OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

ZGW1-1.5/6000 DC Seccionador (6000A)

ZGW1-1.5/6000 DC Seccionador (6000A)

Especificaciones

ModeloZGW1-1.5/6000
NormaIEC 61992-3 (DC seccionadors for railway fixed installations) and metro DC traction power supply technical conditions
Tensión nominal1.5kV DC
Velocidad de diseñoN/A (fixed installation equipment)
MaterialesDedicated DC arc-extinguishing contact system; galvanizado en caliente steel structure; high-strength insulation
InstalaciónMounted in traction substations or trackside boxes; motorized or manual operation

The ZGW1-1.5/6000 is a 1.5kV DC, 6000A high-capacity outdoor seccionador built for high-current metro and urban rail DC traction power supply systems. It provides electrical isolation where very high load currents must be carried and interrupted safely.

Designed with reference to IEC 61992-3 and metro DC traction power supply technical conditions, the switch uses a dedicated DC arc-extinguishing contact system to ensure reliable breaking at corriente nominal. The galvanizado en caliente steel structure and high-strength insulation support long-term outdoor service from -40°C to +70°C at altitudes up to 4,000 m.

Typical installation is inside traction substations or in trackside boxes along the line. Motorized and manual operating mechanisms are both available, allowing integration into automated SCADA-controlled networks or simpler manual installations.

Contact Henan Chuangwit Railway Equipment Co., Ltd. for datasheets, type test reports and project quotations for the ZGW1 high-capacity series.

Frequently Asked Questions

When is the 6000A version required?

On metro lines whose DC traction network sections carry very high currents — typically near substations or on heavily loaded corridors — the 6000A rating provides the required current capacity and breaking reliability.

Which standard applies?

Designed with reference to IEC 61992-3 (DC seccionadors for railway fixed installations) and metro DC traction technical conditions.

Can it be integrated into SCADA systems?

Yes, with the motorized operating mechanism the switch supports remote control and SCADA integration.

Rendimiento

Condiciones de servicio

Long-term outdoor service in high-current metro DC environments from -40°C to +70°C, altitudes to 4,000 m.

Rendimiento mecánico

Heavy-duty galvanized steel frame and high-strength aisladors rated for 6000A continuous current and frequent switching.

Rendimiento eléctrico

Dedicated DC arc-extinguishing contact system ensures reliable breaking at 1500V DC / 6000A per IEC 61992-3.

Aplicaciones

Metro Substations

High-current DC isolation at traction substations.

Heavy Corridors

6000A capacity for heavily loaded DC sections.

Outdoor Service

Galvanized structure for open-air duty.

Regiones frías

Operation down to -40°C.